Electro-Analyzer Model 1000
Eberbach's Electro-Analyzer 1000 apparatus is the laboratory standard for determinations of lead, nickel, copper, zinc, antimony, cadmium and other metals by the electro-deposition process.Unit has a finished steel case (30" high) with stainless steel front surface and occupies a table space of 15" x 17". The front panel protects the apparatus from corrosive spillage and fumes. No electrically corrodible components are positioned where material may fall into the cell and alter results.The unit delivers up to 10 volts, 10 amperes DC at each of two positions for simultaneous determinations. Separate ammeters (0-10A) and center-zero voltmeters (10-0-10V) indicate amount and direction of current flow at each position. Polarity reversing switches change the polarity of the electrodes. Current to each position is supplied by individual power transistors controlled by potentiometers. In line fuses protect AC and DC circuits.Stirrers are driven at a constant speed of 620 rpm by a split-phase induction motor. hollow spindles permit easy vertical adjustment of the glass stirring rods. Power to each stirrer and entire unit is controlled by individual switches with pilot lamps. Heavy-duty platinum electrodes (45 mesh) are recommended for this unit. however, lighter weight electrodes may be used. Spring loaded electrode holders grip the electrodes without deforming the stem and may be moved horizontally for centering nested electrodes. For rotating anode techniques a stainless steel rotating anode holder may be substituted for glass stirring rod.
Dimensions: Width - 15.25" Depth - 16.5" Height - 29.5"
Features:
•Integral Stirrer 620rpm fixed
•Adaptable for use with rotating anode
•115/230V, 50/60Hz
Electro-analysis apparatus for determinations of lead, nickel, copper, zinc, antimony, cadmium and other metals by the electro-deposition process. |
|
HEATER, For Electro-Analyzer 1000, 115V, AC |
|
HEATER, For Electro-Analyzer 1000, 230V, AC |
|
Stainless Steel, For Electro-Analyzer 1000 |
|
AGITATOR, GLASS, 5/16" Dia., 12"L, For Electro-Analyzer 1000 |
|
Eberbach's Model 1100 Electro-Analyzer Anode is a platinum electrode, Stationary type. The 1100 has a 1" diameter, is 2.25" high (overall hight is 5.5") and weights aproximately 22 grams. |
|
The Electro-Analyzer Cathode is a platinum electrode, Stationary type. The 1120 has a 2" diameter, is 2.25" high (overall hight is 5.5") and weights aproximately 31 grams |
|
Eberbach's Model 1140 Electro-Analyzer Anode is a platinum electrode, Rotating type. The 1140 has a 0.5" diameter, is 2" high (overall hight is 5") and weights aproximately 14 grams |

E1020 -115V Heater
E1060 - Glass Agitator
E1100 - Electro-Analyzer Anode
E1120 - Electro-Analyzer Cathode